EN294:1992(ISO/DIS13852)《机械安全防止上肢触及危险区的安全距离》
4.3越过防护结构可及
a危险高度
b防护结构高度
c防护结构近人—侧距危险区的水平距离
高风险越过防护结构可触及的安全距离mm
危险区高度a | 防护结构高度b |
1000 | 1200 | 1400 | 1600 | 1800 | 2000 | 2200 | 2400 | 2500 | 2700 |
距危险区水平距离c |
2700 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
2600 | 900 | 800 | 700 | 600 | 600 | 500 | 400 | 300 | 100 | 0 |
2400 | 1100 | 1000 | 900 | 800 | 700 | 600 | 400 | 300 | 100 | 0 |
2200 | 1300 | 1200 | 1000 | 900 | 800 | 600 | 400 | 300 | 0 | 0 |
2000 | 1400 | 1300 | 1000 | 900 | 800 | 600 | 400 | 0 | 0 | 0 |
1800 | 1500 | 1400 | 1100 | 900 | 800 | 600 | 0 | 0 | 0 | 0 |
1600 | 1500 | 1400 | 1100 | 900 | 800 | 500 | 0 | 0 | 0 | 0 |
1400 | 1500 | 1400 | 1100 | 900 | 800 | 0 | 0 | 0 | 0 | 0 |
1200 | 1500 | 1400 | 1100 | 900 | 800 | 0 | 0 | 0 | 0 | 0 |
1000 | 1500 | 1400 | 1000 | 800 | 700 | |
800 | 1500 | 1300 | 900 | 600 | 0 |
600 | 1200 | 1300 | 800 | 0 | 0 |
400 | 1200 | 1200 | 400 | 0 | 0 |
200 | 1100 | 900 | 0 | 0 | 0 |
0 | 1100 | 500 | 0 | 0 | 0 |
1) 防护结构高度低于1000mm的不包括在内,因其不能有效的限制身体运动。
2) 防护结构低于1400的,如果没有另外防护措施,不应采用。
4.5通过开口触及
4.5.1适用于14岁及以上人的规则开口
表4使用于14岁及以上人用的规则开口安全距离Sr
开口尺寸e表示方形开口的边长、圆形开口的直径和槽型开口的窄边长
身体部位 | 图示 | 开口 | 安全距离Sr |
槽型 | 方形 | 圆形 |
指尖 | | e≤4 | ≥2 | ≥2 | ≥2 |
4<e≤6 | ≥10 | ≥5 | ≥5 |
指至指关节或手 | | 6<e≤8 | ≥20 | ≥15 | ≥5 |
8<e≤10 | ≥80 | ≥25 | ≥20 |
10<e≤12 | ≥100 | ≥80 | ≥80 |
12<e≤20 | ≥120 | ≥120 | ≥120 |
20<e≤30 | ≥850a | ≥120 | ≥120 |
肩至肩关节 | | 30<e≤40 | ≥850 | ≥200 | ≥120 |
40<e≤120 | ≥850 | ≥850 | ≥850 |
如果槽型开口≤65mm,大母手指将受到阻碍,安全距离可减小到200mm。
EN811:9:14(ISO/DIS13853)《机械安全防止下肢触及危险及危险区的安全距离》
防止下肢在防护结构下的自由活动
第一种情况 第二种情况 第三种情况
1基准面 h防护结构高度
2髋关节 l距离
3防护结构
表A1中的距离S适合于人在无支撑时保持站立时限制下肢进入的特定情况
表A1中的数值不能用在滑倒的风险
表A1防护结构高度与限制下肢进入的距离mm
防护结构高度h | 距离l |
第一种情况 | 第二种情况 | 第三种情况 |
h≤200 | ≥340 | ≥665 | ≥290 |
200<h≤200 | ≥550 | ≥765 | ≥615 |
400<h≤600 | ≥850 | ≥950 | ≥800 |
600<h≤800 | ≥950 | ≥950 | ≥900 |
800<h≤1000 | ≥1125 | ≥1195 | ≥1015 |